Сapsule size max. (Ø*H), mm
1000*655
Degassing temperature, °C
300-500
Cooling in vacuum or inert gas to temperature, °C
30-140
Capsule weight max., kg
150
Weight of granules poured into capsule, kg
40-650
Method for controlling the speed of filling capsules with granules
changing the flow area of the dispenser
Chamber volume, m3
4.3
Type of compaction of granules in a capsule
vibration compaction
Oscillation frequency, Hz
10-50
Oscillation amplitude, mm
0.1-1.0
Load capacity of vibrating table, kg
1200
Operating vacuum in the chamber, mm Hg.
5*10-4 - 5*10-5
Time to reach vacuum from the atmosphere to 5*10-3 mm Hg, min.
35
Time to reach vacuum with prepared diffusion pumps from 5*10-3 to 5*10-5 mm Hg. , min.
20
Welding device
Electron beam gun
Electron beam gun beam power max., kW
10
Accelerating voltage, max, kV
60
Residual pressure in the electron gun chamber, mmHg.
5*10-5
Water supply system
reverse + closed
Water pressure in the heat exchangers, MPa
0.2
Internal loop water used
softened, distilled
Power supply voltage, V
400
Phases
3
Frequency Hz
50±1
Power, kW
200
Overall dimensions (L*W*H), mm
7000*4000*2500
Weight, kg
28000